weAr eye protection when disAssembling And cleAning your
shotgun to prevent springs, spring-loAded pArts, solvents or
other Agents from contActing your eyes, resulting in injury.
keep All Ammunition AwAy from the cleAning AreA. never
test the mechAnicAl function of your shotgun with live
Ammunition. fAilure to follow these wArnings could result
in serious injury or deAth.
The Lightning Trigger and bolt can be removed if the action becomes
excessively dirty or wet. If this occurs, disassemble the action for a
complete cleaning as explained in the following sections. The trigger
group and bolt assembly of your Maxus shotgun are designed to be
removed in the field, without special tools.
Disassembly of the action involves the removal of the bolt assembly
and the trigger group. Disassembly beyond this point should only be
performed by a qualified gunsmith.
REMOVING THE TRIGGER GROUP
1 Place the bolt in the forward position by holding the operating
handle and depressing the bolt release button.
NOTICE! never Allow the Action to slAm closed by pressing the
bolt releAse button without the bArrel instAlled. if the bolt is
releAsed forwArd with the bArrel removed, the operAting
hAndle will strike the receiver And cAuse dAmAge.
2 Use a punch or similar object to push inward on the trigger guard
pins, taking care not to scratch the receiver (Figure 27, page 41).
Trigger group pins may be removed from either side of the
receiver. Push the trigger group pins through the receiver. Pull on
them from the opposite side to remove them.
3 Grasp the trigger guard and pull it up and out of the receiver
(Figure 28, page 41).
4 Perform any cleaning of the parts and receiver cavity as necessary.
We suggest cleaning the trigger group with a quality aerosol gun
solvent. Allow it to dry and then very lightly oil the moving parts.
NOTICE! do not disAssemble the trigger group beyond
this point.
REINSTALLATION OF THE TRIGGER GROUP
1 Make sure the bolt is in the forward position.
2 Insert the trigger group into the receiver. Align the holes in the
trigger group with the holes on each side of the receiver.
3 Reinsert the trigger guard pins and gently tap them into place
with a plastic or wooden mallet, again using caution not to
scratch the receiver.
REMOVAL OF THE BOLT ASSEMBLY
before removing the bolt Assembly, plAce the “sAfety” in the on
sAfe position. open the Action And mAke certAin your shotgun
is completely unloAded. keep the muZZle pointed in A sAfe
direction. fAilure to follow these wArnings could result in
serious injury or deAth.
figure 27
Push the trigger group pins through
the receiver.
figure 28
Lift the trigger group from the receiver.
08-121-BFA_Maxus OM.indd 40-41 6/22/09 2:59:59 PM